CNC / DNC Settings for Mazak M Plus and T Plus

Mazak M Plus and T Plus controls require precise serial interface configuration to ensure reliable DNC data exchange. Correctly adjusting user parameters—specifically within group #5—is essential for maintaining a stable communication link between the CNC and your PC. A critical troubleshooting step involves the data bit setting: despite the control's internal 8-bit configuration, your DNC software must be set to 7 data bits to ensure seamless, error-free program transmission. Always verify that your baud rate matches precisely between devices to prevent framing errors, and ensure that your handshake protocol (XON/XOFF) is consistently applied on both ends to avoid buffer overflows during high-speed data transfer or complex tape-mode machining cycles.

Parameter Value Comments
User Parameter #5
G11Baud rate 9600
G232 stop bits
G30Even parity
G538 data bits (Set software to 7)
G61-
G103xOn/xOff flow control (DC1/DC3)
G120No DC2/DC4
G1350-
G1700000000-
G3100000000-
G3350-
G3410-
G3900000100-
G4000000000-
G480-

Note: Even though the Mazak is configured for 8 data bits, ensure your DNC software is set to 7 data bits. Select xOn/xOff flow control within your DNC software settings.