EasyDNC Logo

CNC / DNC Settings for Fanuc 10

Establishing reliable DNC communication for the Fanuc 10 control requires precise serial interface parameterization. Successful drip-feeding (TAPE mode) is contingent upon perfectly matched baud rate, parity, and handshaking protocols (XON/XOFF or hardware flow control). To prevent buffer overflows or transmission data loss, ensure that your PC-side EasyDNC settings exactly mirror the CNC's internal machine parameters. Common pitfalls include mismatched stop bits or cable pinout inconsistencies; verify that your cables are shielded and that the flow control method selected in the software aligns with the machine's I/O configuration. Consistent adherence to these standards ensures stable, error-free program execution during high-speed machining operations.

More information about the RS232-Port and the ALARM 086 (DR SIGNAL OFF / READER NOT READY) can be found here

More information about the ALARM 087 (Buffer Overflow) can be found here

More information about the ALARM 085 (Parity/Communications Error) can be found here

Parameter Value Comments
50011
50022
50033
51103
51112
51129 (Baud Rate)
51203
51212
51229 (Baud Rate)
51303
51312
51329 (Baud Rate) **
6 = 3007 = 600
8 = 12009 = 2400 **
10 = 480011 = 9600
TV On/Off0 = Disabled
Punch Code0 = ISO
Input device1 = 1
Input Device2 = 1
Drip Feed: Select TAPE mode on the controller and press Cycle Start. Then, trigger the transmission from your PC.
Cable Diagram 1

The cable illustrated above is the most frequently utilized configuration, supporting xOn/xOff (software) flow control (DC1/DC3). If your CNC machine is specifically configured for RTS/CTS (hardware) flow control, please refer to the alternative connection diagram provided below, which is generally compatible with both handshaking methods.

Cable Diagram 2